PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specications subject to change without notice.
Install all appliances according to accompanying installation instructions.
7.7
IVS1, IVS2, IVSR1, IVSR2
Integrated Ventilation System
21 1/4"
(54.0 cm)
22 1/2"
(57.2 cm)
6” (15.2 cm)
11 1/16"
(28.1 cm)
12 1/4"
(31.1 cm)
Electrical
access
holes
8" (20,3 cm) round exhaust
with back draft damper
IVS1/IVSR1 OVERALL DIMENSIONS
33 1/4"
(84.5 cm)
34 1/2"
(87.6 cm)
6” (15.2 cm)
11 1/16"
(28.1 cm)
12 1/4"
(31.1 cm)
8" (20,3 cm) round exhausts
with back draft damper
Electrical
access
holes
IVS2/IVSR2 OVERALL DIMENSIONS
21" (53.3 cm)
8" (20.3 cm)
13" (33.0 cm)
10 inch round
2" (5.1 cm)
8" Exhaust
C
L
C
L
IVS1/IVSR1 EXHAUST DIMENSIONS - TOP VIEW
8" Exhaust
C
L
C
L
C
L
C
L
6 1/2"
(16.5 cm)
6 1/2"
(16.5 cm)
IVS2/IVSR2 EXHAUST DIMENSIONS - TOP VIEW
ATD10 DIMENSIONS - FOR USE WITH IVS2 AND IVSR2
(SOLD SEPARATELY)
Model No.
Dedicated Circuit
Required
Maximum
Duct Length
Total
Connected Load
Blower
Configuration
Blower Rating
Approximate
Shipping Weight
IVS1
120 Vac, 60 Hz.,
15 Amp. Min.
grounded,
dedicated circuit
Maximum 60
equivalent
straight feet
0.2 kW (2 Amp.) Internal 600 CFM Nom. 25 lbs.
IVSR1 0.2 kW (1.5 Amp.)* Remote** See REMP specications 21 lbs.
IVS2 0.4 kW (3 Amp.) Internal 1200 CFM Nom. 38 lbs.
IVSR2 0.2 kW (1.5 Amp.)* Remote** See REMP specications 29 lbs.
*
Does not include remote blower.
** Remote blower required. Use only Dacor REMP series remote blower
*** At zero inches static pressure
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.
Document # PG07 - 006
Revised 02/24/10 Page 1/1
WARNING
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
accompanying installation instructions.
NOTE: The Dacor IHL series integrated hood liner is designed for use with
all Dacor IVS series integrated ventilation systems. Together the IVS and
IHL series products can be built into a custom hood structure to provide the
required ventilation and heat resistant, easy to clean surfaces.
Zobrazit stránku 0
1

Shrnutí obsahu

Strany 1 - IVS1, IVS2, IVSR1, IVSR2

PLANNINGGUIDEwww.Dacor.com Phone: (800) 793-0093 Specications subject to change without notice.Install all appliances according to accompanying

Komentáře k této Příručce

Žádné komentáře